News

Thermal Drop Away Ceiling Panels

Apr 28, 2020 3 years ago No Comments
Thermal Drop Away Aisle Containment Panels

Thermal Drop Ceiling Panels Pre-assembled Framed Ceiling Panels Custom Sized for Your Aisle Width Clear Insert is UL Rated to Melt at 135 Degrees Ideal for Cold Aisle Containment Support Frame Can Accommodate Different Height Racks

Read more

Overlapping Aisle Containment Sliding Panels With Active Release and Single-hinged Self-closing Door

May 11, 2016 7 years ago No Comments
aisle containment system diagram

Overlapping Cold Aisle Containment Sliding Panels With Active Release and Single-hinged Self-closing Door 1” flexible gasket accordingly provides seal between cold aisle containment panels and server cabinets. Single or double hinged, self-closing doors Two Panels overlap in the same slide-channel. In addition, release top panel to slide to bottom. Fusible link or magnetic release holds up top panel. Adjustable-sized panels fill gaps between aisle for HAC or CAC and for shorter cabinets.

Read more

Fixed Vertical Hot Air / Cold Air Aisle Containment Panels With Self-Closing Standard Sliding Doors

May 11, 2016 7 years ago No Comments
aisle containment system diagram

Fixed Vertical Hot Air / Cold Air Aisle Containment Panels With Self-Closing Standard Sliding Doors Standard self-closing sliding door. In addition, door opening is 84” x 38” & ADA compliant. Full-height barrier panels fill gaps, as a result cabinet rows prevent hot or cold air leakage. Attach headers to our standard sliding or hinged doors to extend to the height of the cabinets and/or upper aisle containment. The Cool Shield channel frames several types of clear or opaque panels.

Read more

Electronically Activated Magnetic Release Cold Aisle Containment Ceiling Panels with Flexible Strip Doors

May 11, 2016 7 years ago No Comments
hot aisle containment system diagram

Electronically Activated Magnetic Release Cold Aisle Containment Ceiling Panels with Flexible Strip Doors Overlapping strip doors attach directly to ceiling panel framing. Wired electromagnets attach to a junction box. Furthermore, box goes to fire control panel relay or daisy chain to other junction box. Electromagnet holds two light-weight, clear, containment panels at the seam. Full-length hinges allow panels to swing down into cold aisle upon release allowing gas or water based suppression to enter the aisle. Magnets, wires and junction box specifically feature industry-standard 4-pin connectors for simple installation.

Read more

Two-tier Overlapping Flexible Strip For Containment Doors

May 11, 2016 7 years ago No Comments
hot aisle containment system diagram

Two-tier Overlapping Flexible Strip For Containment Doors Strips to fill gaps caused by shorter cabinets cut easily and attached to lower frame. The Cool Shield channel creates a frame around the hot/cold aisle containment area to affix strips at both top and bottom to prevent air leakage. Cool Shield strips specifically have an ASTM E84 Class 1 rating which exceeds data center standards set by NFPA 75. Aisle entry Strip Doors attach to lower framework. 12” wide strips have 3” overlap to maintain air seal.

Read more

Thermally-Activated, Drop-Away Ceiling Panels with Double-Hinged Containment Doors

May 11, 2016 7 years ago No Comments
cold aisle containment system diagram

Thermally-Activated, Drop-Away Ceiling Panels with Double-Hinged Containment Doors Double-hinged doors are self-closing to minimize hot or cold air loss. Clear aisle containment panels can be UL94 or FM Global rated. Thermally activated ceiling panels melt away and harmlessly fall to ground prior to fire suppression release. The Cool Shield channel specifically frames a ceiling at the height of the tallest cabinet. Fixed or adjustable panels extend to tops of shorter cabinets. Attach ceiling frame to cabinet or suspend from above by attaching to ceiling, strut, rod or beams.

Read more

Two-tier Aisle Containment with Solid Panels on Toptier and Removable Flexible Strips on Second-Tier with Self-Closing Extended Sliding Doors

May 11, 2016 7 years ago No Comments
cold aisle containment system diagram

Two-tier Aisle Containment with Solid Panels on Top-Tier and Removable Flexible Strips on Second-Tier with Self-Closing Extended Sliding Doors Self-closing sliding door sized to fully cover server cabinet side panels. Fixed solid panels sized from tallest potential cabinet height to ceiling. 1” gasket attached to top containment channel to creates seal to ceiling and specifically allows for tolerance in floor or ceiling level Removable strip hangers sized to cabinet width and attached to lower channel. Full-height overlapping strip wall maintains cold aisle containment integrity until deploying cabinets.

Read more